Customization: | Available |
---|---|
Certification: | CE, ISO |
Installation Method: |
Vertical |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Heavy Duty Bag Dust Collector for Power Plant or Cement Plant
This dust collector primarily consists of a support frame, hopper, filter chamber, clean air chamber, filter bags, pulse-jet system, and control unit. Designed as a modular unit-combined system, it is available in a series of 1, 2, 3, or 4 units.
Application Scope:
Metallurgy, foundry, mining and mineral extraction, chemical industry, cement, and building materials sectors.
Filter Media:
Airborne particulates, flue gas pollutants, and air containing ultrafine dust.
Unit Specifications:
Each unit contains 24 rows of filter bags, with 12 bags per row.
Total filter bags per unit: 336 (24 rows × 14 bags/row*).
Total filtering area per unit: 800 m².
Filter bag dimensions: Length 6 m × Diameter 130 mm.
Filter bag material: Polyester needle felt.
Model and Specifications | FLZ-800 | FLZ-1600 | FLZ-2400 | FLZ-3200 | FLZ-4800 | |
Number of Units (units) |
1 | 2 | 3 | 4 | 6 | |
Filter Bags (pcs) |
336 | 672 | 1008 | 1344 | 2016 | |
Filter Bag Dimensions (mm) |
Φ130×6000 | |||||
Filter Bag Material | Polyester Needle Felt | |||||
Filtering Area (m²) |
800 | 1600 | 2400 | 3200 | 4800 | |
Filtering Velocity (m/min) |
1.0 | |||||
Airflow Capacity (m³/h) |
48000 | 96000 | 144000 | 192000 | 240000 | |
Equipment Resistance (Pa) |
800-1500 | |||||
Inlet Dust Concentration (g/m³) |
30-100 | |||||
Dust Removal Efficiency (%) |
>99.5 | |||||
Dust RemoDust Remove (%) |
<3 | |||||
Pulse Valve | Specification |
3" Submerged Type | ||||
Quantity | 24 | 48 | 72 | 96 | 144 | |
Pulse Duration (sec) |
0.08 | |||||
Pulse Pressure (MPa) |
0.20-0.25 | |||||
Air Consumption per Valve (m³/cycle) |
0.2-0.25 | |||||
Pulse Interval (sec) |
5-20 | |||||
Screw Conveyor Motor Power (kW) |
2.2 | 3.5 | 4.0 | 5.5 | 7.5 | |
Equipment Weight (ton) |
21 | 36 | 52 | 78 | 118 |
1. What is the working principle of Lefilter Dust Collector?
Answer:
Lefilter dust collector adopts high efficiency filtration technology, through the negative pressure generated by the fan to inhale the dusty gas, the dust is intercepted and filtered by the cartridge (e.g. polyester fiber, film-coated filter material, etc.), and the clean air is discharged. Some models support pulse blowback cleaning system to automatically clean the dust accumulated in the filter element to ensure long-term stable operation.
2. What do I need to pay attention to when installing the dust collector?
Answer:
Make sure the equipment is placed horizontally and away from flammable and explosive environments.
Check the voltage (e.g. 220V/380V) when connecting the power supply, and the grounding wire must be reliable.
The pipe interface needs to be sealed tightly to avoid air leakage affecting the dust suction efficiency.
Before the first startup, check whether the filter element is installed in place and whether the dust cleaning system is normal.
3. How often should the filter element be replaced?
Answer:
Filter cartridge life depends on the use of the environment and the nature of the dust, usually recommended:
Ordinary dust: Replace every 6-12 months.
High humidity, sticky dust: check/replace every 3-6 months.
If a significant drop in suction power or a broken cartridge is found, it needs to be replaced immediately.
4. What may be the reason for the suction power decreasing when the equipment is running?
Answer:
Possible causes include:
Clogged cartridge: clean or replace the cartridge.
Air leakage from pipes or connections: check the sealing.
Dust collection bucket is full: Empty and clean the filter in time.
Failure of the fan: contact after-sales service to test the motor or circuit.
5. How to solve the excessive noise of dust collector?
Answer:
Check whether the equipment is placed smoothly to avoid resonance.
Clean the fan impeller of accumulated dust or foreign matter.
Make sure the silencer (if any) is intact.
If the noise level continues to exceed the limit (>65dB), please contact technical support.
6. What industries are Lefilter dust collectors used in?
Answer:
This series of dust collectors are widely used in:
Industrial dust collection in woodworking, metal processing, laser cutting and so on.
Raw material recovery in chemical and pharmaceutical industries.
Dust control in food and building materials industry.
Please select the specific model according to the dust characteristics (particle size, temperature and humidity, etc.).